| Availability: | |
|---|---|
| Quantity: | |
50μn Hole Accurate test of blood cells with50μn gem hole
Digital Filtering Effectively remove interference
More Reliable
Multi-segment counting method,high anti-interference.
Automatic maintenance and one-click trouble shooting.
Automatic cleaning maintenance of the liquid system at regular intervals.
Intelligent anti-clogging,burning,back flushing and soaking
More durable columnar Pt electrode.
More Convenient
Up to 60 samples/hour.
Cost effective,less sample volume, only 15 uL sample for each test.
No external computer required, automatic result print with in-built printer.
Large touch screen,high-definition color monitor, supporting operation with rubber gloves.
Patented reagent volume detection,ZERO reagent residue.
Coincidence Calibration
Enhance analytical capabilities.
Double Channels
WBC double channels 2D classification, faster and more accurate.
Laser Scattering Method
Blood cell was irradiated by laser one by one when passing through the detection area and the information of cell size internal composition was obtained by measuring the scattered light. Cells were classified according to each information.
More Accurate
Digital filtering,coincidence correction in blood cell counting.
Intelligent laser scattering classification.
The smallest gem hole in the industry with high sensitivity.
Curve fitting,floating threshold technology.
Optical method testing Basophil.

Test Items
White Blood Cell | WBC | Red Blood Cell Specific Volume | HCT |
Neutrophil# | NEU# | Mean Cell Volume | MCV |
Lymphocyte# | LYM# | Mean Corpuscular Hemoglobin | MCH |
Monocyte# | MON# | Mean Corpuscular Hemoglobin Concentration | MCHC |
Eosinophil# | EOS# | Red Cell Volume Distribution Width-Coefficient of Variation | RDW-CV |
Basophil# | BAS# | Red Cell Volume Distribution Width-Standard Deviation | RDW-SD |
Neutrophil% | NEU% | Platelet | PLT |
Lymphocyte% | LYM% | Mean Platelet Volume | MPV |
Monocyte% | MON% | Platelet Distribution Width | PDW |
Eosinophil% | EOS% | Plateletcrit | PCT |
Basophil% | BAS% | Platelet-Large Cell Ratio | P-LCR |
Red Blood Cell | RBC | Platelet-Large Cell Count | P-LCC |
Hemoglobin(Concentration) | HGB | ||
Technical Specifications
Parameters | 5-part WBC Differential |
25 Reportable Parameters | |
2 Histograms | |
2 Scatter Grams | |
Abnormal Sample Alarm | |
Sample Mode | Whole Blood (Venous/Capillary),Pre-dilution |
QC Methods | L-J QC,X-B QC |
Power Supply | 100-240 V~ 50/60 Hz |
Weight | 21 kg |
Dimension | 328 mm x 471 mm x 446 mm (L x W x H) |
Data Storage | 10000 |
Screen Type | 10.4 inch Resistive Screen |
Operating Conditions | 18~30℃,≤80% Relative Humidity,75 kPa~106 kPa |