LDX-50
Product Features Connects to PC software for operation, supports networking, caters to the trend of digital development, and allows for customized uploads. Massive storage capacity: can store at least 1 million (96) test data sheets and 500 programming projects, and supports data backup, recovery, and merging. 24 different projects can be tested on the same board and can be distinguished by display, and qualitative and quantitative projects can be tested on the same board. Template function: standardizes testing work, greatly simplifies the workload of operators; intelligent calculation of test results ensures the accuracy and effectiveness of test results, and can automatically alarm. New Windows color graphical interface, full Chinese operating system, supports mouse and keyboard, and supports multiple input methods. Intelligent light source switch, extending its lifespan. Provides multiple printing methods and various forms of Chinese reports, and can customize various reports. Thirteen calculation methods are available, including absorbance, cutoff threshold, single-point calibration, piecewise linear regression, percentage logarithmic regression, linear regression, logarithmic curve, exponential curve, power curve, 4-parameter regression, percentage logarithmic regression, double logarithmic regression, and enzyme inhibition rate method (optional). Plate layout and save/import functions significantly improve the testing efficiency of commonly used items. A dedicated system maintenance menu automatically determines the instrument's current status and performance indicators, and can print relevant data.
Technical Specifications Wavelength Range: 300-1100nm Filter Configuration: 10 filter positions, standard 405nm, 450nm, 492nm, 630nm, optional 6 custom wavelengths Absorbance Range: 0.000―4.000A Number of Optical Channels: 8-channel optical path detection, plus one independent reference channel (optional) Indication Stability: ≤±0.002A or ≤0.5%T/10min Indication Error (Accuracy): ≤±0.005A or ±0.2%T Repeatability: ≤0.2% or ≤0.2%T Sensitivity: ≥0.01 (L/mg) Channel Difference: ≤0.01A Wavelength Indication Error: ±1nm Half-width: ≤6 nm Peak transmittance: ≥35% Resolution: 0.001A (display), 0.0001A (internal calculation) Reading speed: Single wavelength ≤3 seconds/96 wells, Dual wavelength ≤6 seconds/96 wells Shaking function: Adjustable speed and time Light source type: Halogen tungsten lamp Strip type: Standard 96-well or other types of ELISA plates/strips Applicable well types: Flat bottom, U-shaped, and V-shaped Input method: PC connection Optimal environment: 5℃--40℃, Maximum humidity: 80% Power supply voltage: 220VAC±10%, (50±1)Hz Dimensions: 460mm (L) × 350mm (W) × 197mm (H) Weight: 7.0Kg


Test Items
White Blood Cell | WBC | Red Blood Cell Specific Volume | HCT |
Neutrophil# | NEU# | Mean Cell Volume | MCV |
Lymphocyte# | LYM# | Mean Corpuscular Hemoglobin | MCH |
Monocyte# | MON# | Mean Corpuscular Hemoglobin Concentration | MCHC |
Eosinophil# | EOS# | Red Cell Volume Distribution Width-Coefficient of Variation | RDW-CV |
Basophil# | BAS# | Red Cell Volume Distribution Width-Standard Deviation | RDW-SD |
Neutrophil% | NEU% | Platelet | PLT |
Lymphocyte% | LYM% | Mean Platelet Volume | MPV |
Monocyte% | MON% | Platelet Distribution Width | PDW |
Eosinophil% | EOS% | Plateletcrit | PCT |
Basophil% | BAS% | Platelet-Large Cell Ratio | P-LCR |
Red Blood Cell | RBC | Platelet-Large Cell Count | P-LCC |
Hemoglobin(Concentration) | HGB | ||
Technical Specifications
Parameters | 5-part WBC Differential |
25 Reportable Parameters | |
2 Histograms | |
2 Scatter Grams | |
Abnormal Sample Alarm | |
Sample Mode | Whole Blood (Venous/Capillary),Pre-dilution |
QC Methods | L-J QC,X-B QC |
Power Supply | 100-240 V~ 50/60 Hz |
Weight | 21 kg |
Dimension | 328 mm x 471 mm x 446 mm (L x W x H) |
Data Storage | 10000 |
Screen Type | 10.4 inch Resistive Screen |
Operating Conditions | 18~30℃,≤80% Relative Humidity,75 kPa~106 kPa |