Features
·7 inches color touch LCD screen
·Thermostatic block at +37°C with four stirring systems
·Advanced scattered light principle and percentage analysis produce accurate results
·Special testing cup location system, adding sample bracket
· Advanced optical light matching system, accurate results are guaranteed
· QC function with quality control curve and quality control report
· Calibration curve can be stored, Real-time curve can be stored and researchInternal thermal-sensitive printer
·Memory for 10,000 testing results
·Optional PT Derived method for fibrinogen, decease the dosage of reagent
·Testitems such as PT, APTT, TT, FIB, Clotting factors
·RS232 interface, PC connected
·Open reagent system, close system can be optional
Specification
Testing channels:4 channel, 4 different test in the same time
Sample hot position:24
Reagent hot position:6
Software timers:4
Stirring systems:4
Test wavelength:405nm,660nm
Sample consume:50, 75,100 uL
Reagent consume:50, 75, 100 uL
Temp precision:37+0.3°C
Repeatability CV:≤ 2%
Channel difference CV:≤ 2%
Memory:10000 test results
Format of Result:S, %, PTR, INR, g/L. mg/dL
Optional language:English, French, Spanish, Portuguese, Russian, Indonesian
Interface:USBx2, RS232x1
Bar Code scanner:Bar Code scanner can be connected (Optional)
Power supply:100-240V-50/60Hz
Altitude:≤4500m
Dimension:395mm(L)x320mm(W)x135mm(H)
Temperature:15°C-30°C wet ≤90%
Weight:5KG


Test Items
White Blood Cell | WBC | Red Blood Cell Specific Volume | HCT |
Neutrophil# | NEU# | Mean Cell Volume | MCV |
Lymphocyte# | LYM# | Mean Corpuscular Hemoglobin | MCH |
Monocyte# | MON# | Mean Corpuscular Hemoglobin Concentration | MCHC |
Eosinophil# | EOS# | Red Cell Volume Distribution Width-Coefficient of Variation | RDW-CV |
Basophil# | BAS# | Red Cell Volume Distribution Width-Standard Deviation | RDW-SD |
Neutrophil% | NEU% | Platelet | PLT |
Lymphocyte% | LYM% | Mean Platelet Volume | MPV |
Monocyte% | MON% | Platelet Distribution Width | PDW |
Eosinophil% | EOS% | Plateletcrit | PCT |
Basophil% | BAS% | Platelet-Large Cell Ratio | P-LCR |
Red Blood Cell | RBC | Platelet-Large Cell Count | P-LCC |
Hemoglobin(Concentration) | HGB | ||
Technical Specifications
Parameters | 5-part WBC Differential |
25 Reportable Parameters | |
2 Histograms | |
2 Scatter Grams | |
Abnormal Sample Alarm | |
Sample Mode | Whole Blood (Venous/Capillary),Pre-dilution |
QC Methods | L-J QC,X-B QC |
Power Supply | 100-240 V~ 50/60 Hz |
Weight | 21 kg |
Dimension | 328 mm x 471 mm x 446 mm (L x W x H) |
Data Storage | 10000 |
Screen Type | 10.4 inch Resistive Screen |
Operating Conditions | 18~30℃,≤80% Relative Humidity,75 kPa~106 kPa |