LKH-120
Features:
Sample result, precise reagent dosage, dispensing accuracy: CV<2%, memory for 10,000 test results, internal temperature-sensitive printer, optional electronic pipette, coagulation tests, RS232 interface, PC connection
Low reagent consumption less than 20 pL, open reagent.
Special test cup localization system, additional support
Advanced optical light matching system to ensure
Optional PT-derived method for fibrinogen testing, reducing the
High-quality thermostat, accuracy 37°C + 0.3°C
Perform all routine tests such as PT, APTT, TT, fibrinogen, and fac-
List of common values:
Prothrombin PT
Activated partial thromboplastin time (APTT)
Thrombin time (TT)
Fibrinogen (FIB)
RT, VT, VI, IX, XI, XIII, II, V
VII, X, PS, PC, Xa, etc.
Specifications:
Number of test channels: 2 channels; Simultaneous analysis of 2 different parameters
Sample incubation block: 16 positions
Reagent incubation block: 4 positions
Software timer: 2
Test wavelength: 470 nm
Memory: 10,000 test results
Temperature control accuracy: 37 ± 0.3 °C
Sample consumption: 20 µL–40 µL
Reagent consumption: 20 µL–40 µL
Coincidence indicator: <3%
Result notation: S, %, PTR, INR, g/L
Operating language: English
Display: 240 x 128 LCD
Power supply: 220 VAC ± 15% 50–60 Hz
Dimensions: 395 mm (L) x 320 mm (W) x 135 mm (H)
Working environment Temperature: 15°C–30°C, humidity < 90%
Weight: 6 kg


Test Items
White Blood Cell | WBC | Red Blood Cell Specific Volume | HCT |
Neutrophil# | NEU# | Mean Cell Volume | MCV |
Lymphocyte# | LYM# | Mean Corpuscular Hemoglobin | MCH |
Monocyte# | MON# | Mean Corpuscular Hemoglobin Concentration | MCHC |
Eosinophil# | EOS# | Red Cell Volume Distribution Width-Coefficient of Variation | RDW-CV |
Basophil# | BAS# | Red Cell Volume Distribution Width-Standard Deviation | RDW-SD |
Neutrophil% | NEU% | Platelet | PLT |
Lymphocyte% | LYM% | Mean Platelet Volume | MPV |
Monocyte% | MON% | Platelet Distribution Width | PDW |
Eosinophil% | EOS% | Plateletcrit | PCT |
Basophil% | BAS% | Platelet-Large Cell Ratio | P-LCR |
Red Blood Cell | RBC | Platelet-Large Cell Count | P-LCC |
Hemoglobin(Concentration) | HGB | ||
Technical Specifications
Parameters | 5-part WBC Differential |
25 Reportable Parameters | |
2 Histograms | |
2 Scatter Grams | |
Abnormal Sample Alarm | |
Sample Mode | Whole Blood (Venous/Capillary),Pre-dilution |
QC Methods | L-J QC,X-B QC |
Power Supply | 100-240 V~ 50/60 Hz |
Weight | 21 kg |
Dimension | 328 mm x 471 mm x 446 mm (L x W x H) |
Data Storage | 10000 |
Screen Type | 10.4 inch Resistive Screen |
Operating Conditions | 18~30℃,≤80% Relative Humidity,75 kPa~106 kPa |