When it comes to caring for critically-ill newborns in the Neonatal Intensive Care Unit (NICU), choosing the right non-invasive respiratory device makes all the difference. The LNS-281 non-invasive ventilator is purpose-built to deliver stable CPAP therapy for neonates, helping preserve functional residual capacity and prevent airway collapse for tiny, vulnerable patients.
The LNS-281 integrates complete monitoring and treatment functions for neonatal CPAP support. It provides adjustable CPAP pressure ranging from 0 cmH₂O to 15 cmH₂O, with extended pressure monitoring up to 60 cmH₂O to capture unexpected airway pressure changes.
For gas delivery, the unit offers continuous flow adjustable between 2 L/min-20 L/min, fully covering the typical clinical flow requirement of 4-9 LPM for newborn CPAP. Its built-in air-oxygen blender enables FiO₂ adjustment from 21% to 100%, giving clinicians precise control over oxygen concentration for neonatal patients. Real-time P-T (pressure-time) oscillogram visualises breathing cycles on screen, supporting clinicians to assess patient respiratory status intuitively.
Safety is prioritised with a comprehensive multi-level alarm system. Alarms cover AC power failure, backup battery low-voltage, high/low oxygen concentration, high airway pressure, low gas-source input pressure, blender fault and compressor over-temperature. Every potential risk triggers visual plus audible alerts, protecting neonates during treatment.
Working under universal power input 100-240V, 50/60Hz, the machine fits hospital power conditions across global markets. Its gas source working pressure ranges 280-600 kPa, compatible with central medical gas supply or oxygen cylinders. An internal backup battery provides emergency power in case of mains power interruption for ward transport or unexpected power outages.
The main unit has compact dimensions of 670×480×450 mm with net weight 12 kg, easy to deploy in crowded NICU spaces. A standalone air compressor supplies continuous flow ≥25 L/min and peak flow ≥120 L/min, delivering steady gas output for non-invasive ventilation. Mobile trolley configuration supports intra-hospital transport of unstable newborn patients between departments.
This device fits multiple clinical settings: neonatal intensive care units, delivery rooms, emergency wards and paediatric departments. It applies to non-invasive respiratory support for premature infants and term newborns who need CPAP intervention.
Note: LNS-281 is a medical device for professional clinical use only. Operation must be performed by trained clinical staff in compliance with official user manuals.
If you are sourcing robust neonatal non-invasive CPAP ventilators for hospital projects or tender programmes, the LNS-281 deserves your evaluation for its balanced performance-to-value proposition.