BLOGS
You are here: Home » Blogs » LNS-281 Neonatal Non-Invasive Ventilator: Reliable Respiratory Support for NICU Newborns

LNS-281 Neonatal Non-Invasive Ventilator: Reliable Respiratory Support for NICU Newborns

Views: 0     Author: Site Editor     Publish Time: 2026-10-28      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

LNS-281 Neonatal Non-Invasive Ventilator: Reliable Respiratory Support for NICU Newborns

When it comes to caring for critically-ill newborns in the Neonatal Intensive Care Unit (NICU), choosing the right non-invasive respiratory device makes all the difference. The LNS-281 non-invasive ventilator is purpose-built to deliver stable CPAP therapy for neonates, helping preserve functional residual capacity and prevent airway collapse for tiny, vulnerable patients.

Core Technical Strengths

The LNS-281 integrates complete monitoring and treatment functions for neonatal CPAP support. It provides adjustable CPAP pressure ranging from 0 cmH₂O to 15 cmH₂O, with extended pressure monitoring up to 60 cmH₂O to capture unexpected airway pressure changes.

For gas delivery, the unit offers continuous flow adjustable between 2 L/min-20 L/min, fully covering the typical clinical flow requirement of 4-9 LPM for newborn CPAP. Its built-in air-oxygen blender enables FiO₂ adjustment from 21% to 100%, giving clinicians precise control over oxygen concentration for neonatal patients. Real-time P-T (pressure-time) oscillogram visualises breathing cycles on screen, supporting clinicians to assess patient respiratory status intuitively.

Safety is prioritised with a comprehensive multi-level alarm system. Alarms cover AC power failure, backup battery low-voltage, high/low oxygen concentration, high airway pressure, low gas-source input pressure, blender fault and compressor over-temperature. Every potential risk triggers visual plus audible alerts, protecting neonates during treatment.

Working under universal power input 100-240V, 50/60Hz, the machine fits hospital power conditions across global markets. Its gas source working pressure ranges 280-600 kPa, compatible with central medical gas supply or oxygen cylinders. An internal backup battery provides emergency power in case of mains power interruption for ward transport or unexpected power outages.

Practical Hospital-oriented Design

The main unit has compact dimensions of 670×480×450 mm with net weight 12 kg, easy to deploy in crowded NICU spaces. A standalone air compressor supplies continuous flow ≥25 L/min and peak flow ≥120 L/min, delivering steady gas output for non-invasive ventilation. Mobile trolley configuration supports intra-hospital transport of unstable newborn patients between departments.

Ideal Clinical Scenarios

This device fits multiple clinical settings: neonatal intensive care units, delivery rooms, emergency wards and paediatric departments. It applies to non-invasive respiratory support for premature infants and term newborns who need CPAP intervention.

Note: LNS-281 is a medical device for professional clinical use only. Operation must be performed by trained clinical staff in compliance with official user manuals.

If you are sourcing robust neonatal non-invasive CPAP ventilators for hospital projects or tender programmes, the LNS-281 deserves your evaluation for its balanced performance-to-value proposition.

 


Related Products

content is empty!

Related Blogs
Contact Us
Contact Us

Telephone

+86-025-86160015

WhatsApp

+8615950453904

Add

First Floor West, Building 4, Gaohu Road, Jiangning District, Nanjing City
Quick Links
Home
Product Category
Surgical&ICU Equipment
Dental & ENT Equipment
Dialysis Department
Other Links
Why Choose Us?

Quick Links

Other Links

Copyright © 2025 LONG MEDICAL TECHNOLOGY
CO., LTD. All Rights Reserved.