Mindray BC-10
| Model Number | BC-10 |
| Instrument classification | Class II |
| Warranty | 1 Year |
| After-sale Service | Online technical support |
| Product name | Auto Hematology Analyzer |
| Model | Mindray BC-10 |
| Feature | CBC+3-DIFF, 20 parameters+3Histograms |
| test speet | 30 test/hr |
| keyboard | Only 3 reagents needed |
| Reagents | 4 USB ports |
| Interface | 410*300*400mm |
| Dimension | 4 USB ports |
| keyboard | 8.4inch TFT touch screen |
| Weight | 24 kg |
Technical Specifcations: Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test 20 parameters:WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT Sample Volume Prediluted mode ≤20μL Whole blood mode ≤9 μL Parameters Principles Performance
Parameter Linearity Range Precision (CV %) Carryover WBC(10 9 /L) 0-100 ≤3.5% (4.0-6.9) ≤0.5% ≤2.0% (7.0-15.0) RBC(10 12 /L) 0-8.00 ≤2.0% (3.50-6.5) ≤0.5% HGB(g/L) 0-280 ≤2.0% (100-180) ≤0.5% MCV(fL) ≤1.0% (70.0-110.0) ≤0.5% PLT(10 9 /L) 0-1000 ≤5.0%(100-500) ≤1.0% Throughput 30 samples per hour Display 8.4 inch TFT Touch Screen Multi-language Chinese, English, Spanish,Portuguese, Russian, French, Bahasa Indonesia Data Storage Capacity Up to 50,000 results including numeric and graphicalinformation Communication LAN Port supports HL7 protocol Support bi-directional LIS
Interface 4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1)Printout Thermal recorder, 50 mm wide paper, various printouts formats Power Requirement Temperature: 15°C~30°C Humidity: 10%~90%Air pressure: 70kPa~106kPa Power Requirement (100V-240V)±10% ≤180VA (50Hz/60Hz) ±1Hz Dimension and Weight Dimension: Depth (410mm) x width (300 mm) x height (400 mm) Weight: ≤20Kg

Test Items
White Blood Cell | WBC | Red Blood Cell Specific Volume | HCT |
Neutrophil# | NEU# | Mean Cell Volume | MCV |
Lymphocyte# | LYM# | Mean Corpuscular Hemoglobin | MCH |
Monocyte# | MON# | Mean Corpuscular Hemoglobin Concentration | MCHC |
Eosinophil# | EOS# | Red Cell Volume Distribution Width-Coefficient of Variation | RDW-CV |
Basophil# | BAS# | Red Cell Volume Distribution Width-Standard Deviation | RDW-SD |
Neutrophil% | NEU% | Platelet | PLT |
Lymphocyte% | LYM% | Mean Platelet Volume | MPV |
Monocyte% | MON% | Platelet Distribution Width | PDW |
Eosinophil% | EOS% | Plateletcrit | PCT |
Basophil% | BAS% | Platelet-Large Cell Ratio | P-LCR |
Red Blood Cell | RBC | Platelet-Large Cell Count | P-LCC |
Hemoglobin(Concentration) | HGB | ||
Technical Specifications
Parameters | 5-part WBC Differential |
25 Reportable Parameters | |
2 Histograms | |
2 Scatter Grams | |
Abnormal Sample Alarm | |
Sample Mode | Whole Blood (Venous/Capillary),Pre-dilution |
QC Methods | L-J QC,X-B QC |
Power Supply | 100-240 V~ 50/60 Hz |
Weight | 21 kg |
Dimension | 328 mm x 471 mm x 446 mm (L x W x H) |
Data Storage | 10000 |
Screen Type | 10.4 inch Resistive Screen |
Operating Conditions | 18~30℃,≤80% Relative Humidity,75 kPa~106 kPa |