| Availability: | |
|---|---|
| Quantity: | |
R100
Adjustable Treatment Modes: The PAP device offers both CPAP (Continuous Positive Airway Pressure) and Auto CPAP treatment modes, allowing for customizable operating pressure to suit individual needs.
Leakage Detection: With its advanced technology, the device detects mask leakage and promptly notifies users of any leaks or errors, ensuring consistent and effective therapy.
Air Leakage Compensation: The device automatically compensates for air leakage within a specified range, optimizing therapy efficiency.
Patient Information Storage: It conveniently stores patient information, making it easy to track and monitor treatment progress over time.
Intelligent Mask Recognition: The PAP device can intelligently recognize whether the mask is worn or removed, enabling automatic treatment start and stop functions.
Customizable Settings: Users can set Ramp time and adjust humidity levels from 1 to 6, tailoring the therapy experience to their comfort and preferences.
Auto Pressure Release: For added safety and comfort, the device includes an auto-pressure release feature.
Multiple Reminder Functions: The PAP device offers a range of reminder functions to ensure users never miss a therapy session or maintenance tasks.
The Positive Airway Pressure device is a user-friendly, high-performance solution for those seeking effective OSA therapy. Whether you're using it at home, in a clinic, or in a hospital setting, this portable device empowers individuals to take control of their sleep apnea treatment, providing relief and improved sleep quality. Say goodbye to sleepless nights and hello to restful, rejuvenating sleep with the PAP device.
Operating Pressure:
1)Operating pressure range:4 cmH2O~20 cmH2O(4~ 20 hPa)
2)Resolution ratio :0.1cmH2O(0.1 hPa)
3)Dynamic variation range:0.2 cmH2O(0.2 hPa)
Ramp Time:
1)Operating range:0~45 min
2)Resolution ratio :1min
3)Dynamic variation range:5 min
Power:
1)Input:100-240 V~,50-60 Hz;1.5 A MAX
2)Output:DC 24 V 3.75 A
Humidifier:
1)Volume:200ml~360ml
2)Consumption:≤48W
3)Materials: PC, Stainless steel chassis
4) Maximum temperature of hating plate:63℃ (±3℃)
5)The air outlet temperature of Breathing tube:≤41℃
6)Thermal circuit breaker: disconnection>85±5℃, recovery<55±15℃, delay< 10s, DC24V-3A,
7)Protective disconnection temperature: 76℃
Safety Classification:
1)(Anti-electric shock level ) : Class II and Type BF applied part
2)SpO2 Device:Class I laser product
3)Ingress protection:IP22
SpO2 Measurement:
1)Measurement range:0%~100%
2)Resolution ratio:1%
3)Accuracy:±2%
PR Measurement:
1)Measurement range:30 bpm~250 bpm
2)Resolution ratio:1bpm
3)Accuracy:±2 bpm or ±2% of the maximum
Noise:
1)Pressure is 10 cmH2O, distance is 1m, normal operation (including humidifier) noise ≤35dB
Operating Measurement:
1)Flow Sensor ±500Pa
2)Pressure Sensor 0~45 cmH2O(0~45 hPa)
Breathing tube (Breathing circuit)
Breathing tube (Breathing circuit) Specification
Micro SD Card
SpO2 Device (Optional)
Mask
Mask Specification
Power Supply Unit
Power adapter cord
Air Inlet Filter Cotton
Portable bag
The User Manual
Reminder: Breathing tube (Breathing circuit) refer to the physical products.
| Dimensions | 275*170*145 mm |
| Breathing tube | Soft plastic, length is 1.8m, outlet complies with ISO5356.1 22mm conical joint |
| Weight(device and cleanable humidifier) | 1600g |
| Work Environment | a)Operating Temperature:+5 ℃~+40 ℃ |
| b)Relative Humidity:10%~95%, non-condensing | |
| c)Atmospheric Range (non-condensing):700 hPa~1060 hPa |
content is empty!